This object provides access to the HDMI® CEC channel.
Object Creation: The roCecInterface object is created with no parameters.
CreateObject("roCecInterface") |
When possible, JavaScript APIs should be used instead of BrightScript-Javascript Objects. The JavaScript API equivalent to this object is cec.
Sends a message on the CEC bus. The frame data should be provided as an roByteArray, with the destination address in the low 4 bits of the first octet.
The system software automatically replaces the high 4 bits of the first octet with the source address. It also copies the physical address of the player into the following messages automatically prior to transmission: ActiveSource, InactiveSource, SystemAudioModeRequest.
As of BrightSign OS 8.2.55, the CEC implementation for AU series 5 products will reply to these messages with the correct data, without involving the script:
CEC_MSG_GET_CEC_VERSION
CEC_MSG_ABORT
CEC_MSG_GIVE_DEVICE_POWER_STATUS
CEC_MSG_GIVE_OSD_NAME
CEC_MSG_GIVE_DEVICE_VENDOR_ID
CEC_MSG_GIVE_FEATURES
CEC_MSG_GIVE_PHYSICAL_ADDR
CEC_MSG_USER_CONTROL_PRESSED
CEC_MSG_USER_CONTROL_RELEASED
CEC_MSG_REPORT_PHYSICAL_ADDR
As of BrightSign OS 8.2.55, the CEC implementation for AU series 5 products will reply to these messages with the correct data, without involving the script:
CEC_MSG_GET_CEC_VERSION
CEC_MSG_ABORT
CEC_MSG_GIVE_DEVICE_POWER_STATUS
CEC_MSG_GIVE_OSD_NAME
CEC_MSG_GIVE_DEVICE_VENDOR_ID
CEC_MSG_GIVE_FEATURES
CEC_MSG_GIVE_PHYSICAL_ADDR
CEC_MSG_USER_CONTROL_PRESSED
CEC_MSG_USER_CONTROL_RELEASED
CEC_MSG_REPORT_PHYSICAL_ADDR
Tip Use the |
Removes the source address included in CEC messages by system software if passed true
. This method allows you to transmit unmodified bytes via CEC.
Returns the current logical address. This method will return the unregistered address (0x0f) to indicate that the logical address has not been negotiated. In this case, messages can still be sent, but the receivers will behave differently and may not process all messages.
Enables CEC debugging. This method will write a log of all CEC packets to the specified file.
Returns the CEC physical address, which is sometimes required when processing CEC messages.
Optional. This can be:
default: the default output for the platform, normally HDMI-1
HDMI-X : X is a number from 1 up to the number of HDMI outputs on the platform
eARC: on the AU335 (the default)
Sets the user data that will be returned when events are raised.
Returns the user data that has previously been set via SetUserData(). It will return Invalid if no data has been set.
Posts messages of type roCecRxFrameEvent and roCecTxCompleteEvent to the attached message port.
ON THIS PAGE |