SSD Requirements and Recommendations
The XCx55, XDx35, XTx45, XTx44, XTx43, XDx34 and XDx33 models can be installed with an internal SSD device. This page outlines the required and recommended specifications for SSD drives installed in BrightSign players. See the SSD Installation page for SSD installation steps.
Required Specs
Connector Type
The XCx55, XTx45, XDx35, XTx44, XDx34, XTx43, and XDx33 all have an M-keyed M.2 connector.
SSD Size
XCx55, XTx45, XDx35, XTx44, XDx34: 2242, 2280
XTx43, XDx33:Â 2242, 2260, 2280
Logical Device Interface
XCx55, XTx45, XDx35, XTx44, XDx34: NVMe
XTx43, XDx33:Â ATAPIÂ
Important
Because the SSD interface differs between the XTx43/XDx33 and XTx44/XDx34 (ATAPI vs. NVMe), SSD drives intended for the XTx43/XDx33 cannot be transferred to the XTX44/XDx34, and vice-versa.
Recommended Specs
Sequential read: Up to 520 MB/s
Sequential write: Up to 330 MB/s
Random read: Up to 33000 IOPS
Random write: Up to 62000 IOPS
Mean time to failure (MTTF): 1750000 hours
Thermal management: Dynamic throttling
Operating Temperature: 0°C to 70°C
Operating Humidity (non-condensing): 5% to 95%
Operating vibration: 5gRMS, 10-2000Hz, 3 axes
Operating Shock: 1000G, 1.0ms Half Sine pulse duration
ESD (contact): +/- 4kV
ESD (air): 8kV
EMI Standards
FCC 47 Part 15 Class B
IECS-003 Class B
EN 55022 Class B
EN 55024
KCC KN22
KCC KN24
CNS 13438 2006
VCCI rules and regulations
AS/NZS CISPR 22:Â 2009
Certifications
EMI/EMC
FCC 47CFR Part 15 Subpart B class B
ICES-003 Issue 5
EN 55022:2006, A1:2007, A2:2010
EN 55024:2010
VCCI V-3/2011.04
AS/NZS CISPR 22:2009
BSMI CNS 13438:2006
Safety
UL 60950-1, 2nd Ed., 2007-03-27
CSA C22.2 No. 60950-1-07, 2nd Ed., 2007-03
IEC 60950-1:2005 (2nd Ed.)
EN 60950-1:2006 +A11
Other
2004/108/EC
2006/95/EC